top of page
< Back

Co2 Insufflator

Performance Features:

Software:
Software controlled technology to initiate calibration of pressure and flow of system when insufflator is turn on. Software controlled pressure release mechanism to prevent excess pressure build up in abdomen.
​

Inbuilt Gas Warmer:
The Co2 insufflator has unique heating systems that provides a constant temperature for the Co2 to reduce chill effect of high flow insufflation & lenses telescope fogging.
​

Advance Flow Control:
The Co2 insufflator is highly adaptable advance flow control insufflation for precise and safe gas flow to meet patient requirement.Better precision for measurement of volume & flow of Co2.The Co2 has pressure range from 4 to 30 mm Hg.

​
Safety:
Special feature that assures a constant pressure of the Co2.If actual pressure is more than set pressure, the system offers a rapid & instantaneous release over. Low gas pressure alarm & pressure release systems helps to assure patient safety.

Highlights :-

- High Pressure Co2 from the main cylinder can be connected direct to the insufflator.
- Micro Controller based closed loop technology ensures precise control of pressure/flow parameters.
- Electronic memory retains last set values of pressure, flow rate and pumped gas volume.
- Inbuilt gas warmer provides warm Co2 at trocar minimizing fogging and all disadvantages of
Chilled gas entering abdomen.
- Continuous gas flow controller ensures stable abdominal distention during surgery.
- Functional and user – friendly design.
- Compact & light weight.
- Various safety features & meets quality standards.
- Rapid delivery of gas & provide immediate response for procedures.

Front Panel Displays and Controls:
Veress/trocar mode.
Separate digital display for actual value and set value of pressure and flow rate.
Pumped gas volume counter with Reset button.
Display for actual gas consumption & temperature
Outlet gas temp with heater on indicator.
Co2/Air mode button for emergency.
Co2 gas status indicator.

Technical Specifications

PNEUMATICS
Gas: Co2 (Medical)
CO gas Supply system: UNF 7/16”.2
Insufflation pressure Min. to Max. : 4 - 30 mm Hg (To an accuracy of 1 mm Hg)
Flow Rate min to max. : 1 to 30 ltrs/Min continuous
Internal over pressure release value
Output connection – 6 to 7 mm ID tube

INTERFACE
7 Segment display: Showing set & actual pressure, set & actual flow, Temperature & Gas consumption
Keyboard – feather touch

POWER SUPPLIES
230 VAC + 15% @ 50 - 60 HZ.

Protection by fuse : 5A

Power consumption – 125W Max with warmer else 20W Max


MECHANICS
Enclosure : Metal body
Dimension: 260(L) mm x 290 (W) mm x 105(H) mm
Weight: Approx: 5kg